postslpo.blogg.se

Ontario building code wood stove clearances
Ontario building code wood stove clearances









Copy of the deed or tax bill (proof of land ownership - if required).A completed setback waiver/inspection form.Stove pipe documentation and/or Chimney documentation.Appliance documentation – installation requirements of the appliance with clearances to combustible materials and floor protection.This project will require the following documents: To apply for a wood burning appliance permit please complete this application. This includes any alteration to existing installations and replacements of part of or all of a system. The Ontario Building Code regulates the installation of solid fuel burning appliances including masonry fireplaces, free-standing wood and pellet stoves and fireplace inserts.

ontario building code wood stove clearances

Diameter of Round Flues forįireplace Chimneys Forming Part of Sentence 9.21.2.5.Wood, Pellet Stoves and Wood Burning Fireplaces Masonry Flue Size Requirements Table 9.21.2.5.A. Top mount, rain cap etc are to be installed similar to installing a liner for an insert. The SS liner will require spacing - brackets for the required air gap \ clearances or utilize compliant insulation or an insulated liner. The liner will need to be connected to a bottom plate (mesh), and either create a transition (site built) or utilize a fabricated transition box (factory built) from the throat to the liner. Alternatively, a mechanical ventilation system may be used with a smaller diameter of liner (P.Eng or listing certification required). There are some large, "commercial" liner options available, but a custom bottom plate will still likely require fabrication. Most liner manufacturers have a limited size, so if the opening is large, fabrication of a custom liner is may be needed. of the Building Code and appease other requirements as outlined in 9.21. A liner diameter that fulfills the requirements outlined in 9.21.5.2. To reline with a stainless steel liner, consideration of the size of the masonry fireplace opening must be installed.

ontario building code wood stove clearances

As this is on an individual basis, many factors may dictate what you may require or if approval will be granted at all. If the products have not been tested and listed for use, a report by a Mechanical Engineer, stamped (P.Eng) with all the product specs, drawings along with the applicable codes may be accepted by your AHJ. When installing factory built components they all must be tested and listed under the appropriate listing standards. When considering relining a masonry fireplace \ chimney (site built), one must appease the local AHJ (Authority Having Jurisdiction), Building Code and any applicable Installation Codes.











Ontario building code wood stove clearances